Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Cardiol ; 388: 131151, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37423572

RESUMO

BACKGROUND: Despite optimizations of coronary stenting technology, a residual risk of in-stent restenosis (ISR) remains. Vessel wall injury has important impact on the development of ISR. While injury can be assessed in histology, there is no injury score available to be used in clinical practice. METHODS: Seven rats underwent abdominal aorta stent implantation. At 4 weeks after implantation, animals were euthanized, and strut indentation, defined as the impression of the strut into the vessel wall, as well as neointimal growth were assessed. Established histological injury scores were assessed to confirm associations between indentation and vessel wall injury. In addition, stent strut indentation was assessed by optical coherence tomography (OCT) in an exemplary clinical case. RESULTS: Stent strut indentation was associated with vessel wall injury in histology. Furthermore, indentation was positively correlated with neointimal thickness, both in the per-strut analysis (r = 0.5579) and in the per-section analysis (r = 0.8620; both p ≤ 0.001). In a clinical case, indentation quantification in OCT was feasible, enabling assessment of injury in vivo. CONCLUSION: Assessing stent strut indentation enables periprocedural assessment of stent-induced damage in vivo and therefore allows for optimization of stent implantation. The assessment of stent strut indentation might become a valuable tool in clinical practice.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Lesões do Sistema Vascular , Animais , Ratos , Doença da Artéria Coronariana/patologia , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica/métodos , Vasos Coronários/patologia , Resultado do Tratamento , Neointima/diagnóstico por imagem , Neointima/patologia
2.
J Cell Mol Med ; 23(1): 39-46, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30353645

RESUMO

Coronary artery stenting following balloon angioplasty represents the gold standard in revascularization of coronary artery stenoses. However, stent deployment as well as percutaneous transluminal coronary angioplasty (PTCA) alone causes severe injury of vascular endothelium. The damaged endothelium is intrinsically repaired by locally derived endothelial cells and by circulating endothelial progenitor cells from the blood, leading to re-population of the denuded regions within several weeks to months. However, the process of re-endothelialization is often incomplete or dysfunctional, promoting in-stent thrombosis and restenosis. The molecular and biomechanical mechanisms that influence the process of re-endothelialization in stented segments are incompletely understood. Once the endothelium is restored, endothelial function might still be impaired. Several strategies have been followed to improve endothelial function after coronary stenting. In this review, the effects of stenting on coronary endothelium are outlined and current and future strategies to improve endothelial function after stent deployment are discussed.


Assuntos
Angioplastia Coronária com Balão/métodos , Constrição Patológica/fisiopatologia , Estenose Coronária/fisiopatologia , Endotélio Vascular/fisiopatologia , Stents , Animais , Proliferação de Células , Constrição Patológica/cirurgia , Estenose Coronária/cirurgia , Células Endoteliais/citologia , Células Endoteliais/fisiologia , Humanos , Miócitos de Músculo Liso/citologia , Miócitos de Músculo Liso/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...